2X12MTP Male to 2x6Duplex LC/UPC Multimode OM4 10Gbs Cassettes, for Fast Installations in Rack Mount or Wall Mount Enclosures

2X12MTP Male to 2x6Duplex LC/UPC Multimode OM4 10Gbs Cassettes, for Fast Installations in Rack Mount or Wall Mount Enclosures

P/N: AIF-CST-OM4-24MTPLC

AIFIBER’s MPO MTP® cassettes provides data transmission between secure MPO MTP® and LC or SC,MPO MTP® Modulars offer an easy and flexible way to reconfigurate the high density data infrastructure

Share: share to Facebook   share to Twitter
Description

AIFIBER AMC series MTP cassettes come in a variety of connector styles and modes. From Multimode to Singlemode, from SC to LC. MTP cassettes can be your solution to save space, time, and energy.
The cassette itself is comprised of four parts: 
 
 •MTP brand adaptor(s) in back
 •MTP brand connectors to SC/LC fan out assembly inside the cassette
 •SC, ST, MTRJ (including keyed MTRJ), and LC (including keyed LCs) adaptors in the front
 •The AL power coated cassette module housing
 
By plugging an MTP brand cable into the back, you're lighting up 12 or 24 (with quad LC) connections. For the 24-fiber application, you can have either one 24-fiber MTP brand cable or two 12-fiber MTP brand cables (plugging into two ports). 
 
The cassette can be snapped into any standard fiber optic patch panel including both rack mount and wall mount. All it takes is one port! The RME1U enclosure can hold three of these cassettes which could potentially give you 72 active LC connections using only three (or six) MTP brand cables. Normally, you would have a patch panel that has straight-through adapter panels and would need dozens of duplex patch cords plugging into the back of them. Clean up the clutter and increase your possibilities using MTP brand cassettes. 


Applications
 
Data Center infrastructure
Distribution area connections
Storage Area Network
 
 
Features
 
High grade LC or SC connectors
High performance zironic sleeve adaptors
Compliant to IEC-61754-7&EIA/TIA-604-5


Specification
 
a. MTP  ® Connector

 
MTP ® Connector
Standard
SM MT
Ferrule
Elite
SM MT
Ferrule
Standard
MM MT
Ferrule
Elite
MM MT
Ferrule
Polish APC APC UPC UPC
Insertion Loss(dB) Typical 0.25 0.10 0.25 0.10
Maximum 0.30 0.30 050 0.30
Return Loss(dB) 50 60 30 30
Operating Temperature(℃) -40~+80
Storage Temperature(℃) -40~+80


b.MPO Connector 

MPO Connector Standard
SM MT Ferrule
Low Loss
SM MT Ferrule
Standard
MM MT Ferrule
Low Loss
MM MT Ferrule
Polish UPC APC UPC APC UPC UPC
Insertion Loss(dB) Typical 0.5 0.5 0.3 0.3 0.5 0.3
Maximum 0.7 0.7 0.5 0.5 0.7 0.5
Return Loss(dB) 45 60 60 45 20 20
Exchangeability(dB ) ≤0.3
Durability(dB) <0.2(500Matings,per EIA-455-21A)
Tensile Strength(dB) ≤0.3(Max 66N)
Operating Temperature (℃) -20~+60
Storage Temperature(℃) -40~+80















 

Associated Standards
* Meets IEC Standard 61754-7 and TIA/EIA 604-5 Type MPO
* Structured cabling per TIA-568-C
* Parallel Optics
- Optical Internetworking Forum (OIF) Compliant
- Infiniband Compliant
- 10G Fiber Channel Compliant
- 40G and 100G IEEE 802.3
- SNAP 12
- POP 4
- QSFP

LC,SC Connector
a. Multimode OM1/OM2/OM3/OM4    0.2dB(IL Max)  35dB(RL Min)
b. Singlemode OS1/OS2             0.2dB(IL Max)   55dB( RL Min)

24Fibers MTP to 12Duplex LC/UPC Cassette Drawing